Friday, September 30, 2011

hydraulic pump

Hydraulic pump Rexroth A4VSO250
Gearpump with external teeth
Gearpump with internal teeth
A gerotor (image does not show intake or exhaust)
Fixed displacement vane pump
Principle of screw pump
Axial piston pump, swashplate principle
Radial piston pump
Hydraulic pumps are used in hydraulic drive systems and can be hydrostatic or hydrodynamic.
Hydrostatic pumps are positive displacement pumps while hydrodynamic pumps can be fixed displacement pumps, in which the displacement (flow through the pump per rotation of the pump) cannot be adjusted, or variable displacement pumps, which have a more complicated construction that allows the displacement to be adjusted.
Gear pumps (with external teeth) (fixed displacement) are simple and economical pumps. The swept volume or displacement of gear pumps for hydraulics will be between about 1 cm3 (0.001 litre) and 200 cm3 (0.2 litre). These pumps create pressure through the meshing of the gear teeth, which forces fluid around the gears to pressurize the outlet side. For lubrication, the gear pump uses a small amount of oil from the pressurized side of the gears, bleeds this through the (typically) hydrodynamic bearings, and vents the same oil either to the low pressure side of the gears, or through a dedicated drain port on the pump housing. Some gear pumps can be quite noisy, compared to other types, but modern gear pumps are highly reliable and much quieter than older models. This is in part due to designs incorporating split gears, helical gear teeth and higher precision/quality tooth profiles that mesh and unmesh more smoothly, reducing pressure ripple and related detrimental problems. Another positive attribute of the gear pump, is that catastrophic breakdown is a lot less common than in most other types of hydraulic pumps. This is because the gears gradually wear down the housing and/or main bushings, reducing the volumetric efficiency of the pump gradually until it is all but useless. This often happens long before wear causes the unit to seize or break down.
Total head and flow are the main criteria that are used to compare one pump with another or to select a centrifugal pump for an application. Total head is related to the discharge pressure of the pump. Why can't we just use discharge pressure? Pressure is a familiar concept, we are familiar with it in our daily lives. For example, fire extinguishers are pressurized at 60 psig (413 kPa), we put 35 psig (241 kPa) air pressure in our bicycle and car tires.For good reasons, pump manufacturers do not use discharge pressure as a criteria for pump selection. One of the reasons is that they do not know how you will use the pump. They do not know what flow rate you require and the flow rate of a centrifugal pump is not fixed. The discharge pressure depends on the pressure available on the suction side of the pump. If the source of water for the pump is below or above the pump suction, for the same flow rate you will get a different discharge pressure. Therefore to eliminate this problem, it is preferable to use the difference in pressure between the inlet and outlet of the pump.

The manufacturers have taken this a step further, the amount of pressure that a pump can produce will depend on the density of the fluid, for a salt water solution which is denser than pure water, the pressure will be higher for the same flow rate. Once again, the manufacturer doesn't know what type of fluid is in your system, so that a criteria that does not depend on density is very useful. There is such a criteria and it is called TOTAL HEAD, and it is defined as the difference in head between the inlet and outlet of the pump.

You can measure the discharge head by attaching a tube to the discharge side of the pump and measuring the height of the liquid in the tube with respect to the suction of the pump. The tube will have to be quite high for a typical domestic pump. If the discharge pressure is 40 psi the tube would have to be 92 feet high. This is not a practical method but it helps explain how head relates to total head and how head relates to pressure. You do the same to measure the suction head. The difference between the two is the total head of the pump.

Figure 25

The fluid in the measuring tube of the discharge or suction side of the pump will rise to the same height for all fluids regardless of the density. This is a rather astonishing statement, here's why. The pump doesn’t know anything about head, head is a concept we use to make our life easier. The pump produces pressure and the difference in pressure across the pump is the amount of pressure energy available to the system. If the fluid is dense, such as a salt solution for example, more pressure will be produced at the pump discharge than if the fluid were pure water. Compare two tanks with the same cylindrical shape, the same volume and liquid level, the tank with the denser fluid will have a higher pressure at the bottom. But the static head of the fluid surface with respect to the bottom is the same. Total head behaves the same way as static head, even if the fluid is denser the total head as compared to a less dense fluid such as pure water will be the same. This is a surprising fact.
Hydraulic Specialists, Inc. known as HSI was founded in 1979. With over 200 years of combined hydraulic experience and is proudly celebrating its 32nd year in business.  HSI remanufactures hydraulic components such as pumps, motors, valves, presses and power units.  We handle all lines of OEM's such as Oilgear, Vickers, Rexroth, Racine, Denison, HPM, Eaton, Hagglunds, Sunstrand to name a few.  We offer our customers an alternative to going back to the OEM which tend to have long lead times and high pricing.  We remanufacture current units but our niche is in the obsolete units. HSI also has an "Open Door" Policy... If you would like to come and tour our facilities or watch your unit being evaluated, assembled or tested we invite you to do so....


Hydraulic pump sits at idle dumping over a dump valve to unload the pump. Clamp command is given and the dump valve is energized to prevent oil flowing directly to the tank. Once the clamps have been completed and pressure is at the maximum, the pressure switch actuates and shuts off the clamp solenoid and dump valve. Therefore, unloading the oil from the pump to tank. The clamps maintain pressure because of a P.O. check installed in the valve stack. If the P.O. check leaks or there is excessive leakage the hydraulic pump can be set up to perform a recharge though this is often not required. If a recharge is required the PLC will control the logic and dual setting pressure switches are needed for safety check. The first pressure switch set point will control the recharge point and the second will be the pressure at which will fault the machine if reached during the machining cycle. If the system recharges more then lets say 3 times in a minute, the system alarms out due to excessive cycling which can all be set up in the PLC. Unclamp and clamp circuits can both work under this concept though a recharge is not often needed for the unclamp. Single actuating and double actuating fixtures can be different to save costs, but this type of design setup should work for just about any fixture you would ever want to put on it.

Variable flow Compensator hydraulic systems

This type of system is generally a higher flow pump and much more costly. This system generally requires an oil cooler and flow control valves in the valve stacks, due to higher flow rates. These type of systems are also generally lower pressure systems, typically 2000 PSI or less.
Basic operation
These pumps have basically pistons attached to a plate. When there is a need for flow, the plate shifts increasing the stroke of the pistons and therefore it outputs more flow. This system always runs at full system pressure. When there is no oil flow there is no load because the plate with the pistons is vertical and there is no load. A relief valve is provided for safety but should never see any oil going over it in normal operation if set correctly. This type of system works well because it keeps constant pressure on the system and does not rely on P.O. checks holding pressure at the clamps. With this system you should still have P.O. checks incase the pump shuts off during the machining cycle.

Air over oil Pump systems

These systems are the cheapest of all systems. Depending on the brand and design you may have problems. They are very simple low volume/flow systems. They generally work well when using 2-4 valve stacks that are sequenced and do not require high volume of oil.
Basic operation
Air is supplied to the system. Air will cycle an intensifier type cylinder and push oil from a reservoir into the hydraulic system. Pressure is adjusted by adjusting the incoming air flow.

High Pressure coolant systems buying considerations, efficiency, and coolant system applications

High pressure coolant can be very beneficial for almost any job, some much more then others. The benefits of the high pressure coolant usually out weigh the initial cost when it comes to tooling savings, cycle time and finish. Tooling will last longer, speeds will be increased especially when drilling or boring. High pressure coolant will keep the part from heating up by transferring the heat into the coolant, away from the tool and part. Therefore, holding tighter tolerances, keeping your chips consistent and heat free. Learn to turn, mill, and drill faster with high pressure coolant.

Benefits of high pressure coolant

  • Often drastic cycle time reduction (20-70%)

  • Increased speeds in hole production

  • Eliminate heat related failure of insert

  • Reduced chip welding and "built-up edge" in aluminum machining

  • Better chip control in Low Carbon Steels

  • Improved quality and speed of Threaded Holes

  • Reduce or eliminate work hardening from peck drilling

  • Improved tapping in tough materials

  • Increased life of expensive Custom Tooling

  • Improved Auto-loading by eliminating chip problems

  • Increased tool life in Abrasive Materials


    The basic hydraulic pump system

    The basic unit will contain a .5-1.0 GPM pump which will be sufficient for the majority of fixtures unless you are using larger volume of clamps or multiple operations at once. The size of the motor depends on the pressure needed - 1,3,5(HP) horse power. The pump reservoir size is usually a 1, 3 or 5 gallon. The pump system should also contain an oil low level and HI-temperature switch for protection. Pump specs for volume can be calculated by figuring out the total volume of the clamps and figuring the speed at which the chamber fills up assuming .5 gal per minute.
    The hydraulic valving for a double acting fixture (can also be used for single acting)
  • Directional control valves- Poppet (Least expensive,preferred for low flow small systems) or spool type (can handle more contaminants in oil)
  • P.O. check valves on A+B
  • Tapping Block for pressure switches on A and B
  • Pressure switches on A+B (Sometimes only A port I'll explain later)
  • Dump valve
  • Pressure reducing valve (not usually needed)
  • Flow controls (not usually needed- used usually with small volume work supports)

Hydraulic pressure switch considerations

Hydraulic pressure switches may not be necessary on B port if it is a single actuating fixture. If it is a single actuating fixture with a robot load, I would recommend them to confirm that there is no residual pressure left on the clamp side. Then causing the robot to collide with the clamps.
Also, if it is a manual operation only the PLC may run the unclamp solenoid for a specified amount of time instead of waiting for the unclamp pressure switch to be made. However; if there is any safety concerns during the unclamp cycle where the operator can be injured, this may not be a good idea.


Tuesday, September 27, 2011

Hydro electricity

The Gordon Dam in Tasmania is a large hydro facility, with an installed capacity of 430 MW.
Renewable energy
Wind turbine
Biofuel
Biomass
Geothermal
Hydroelectricity
Solar energy
Tidal power
Wave power
Wind power
Hydroelectricity is the term referring to electricity generated by hydropower; the production of electrical power through the use of the gravitational force of falling or flowing water. It is the most widely used form of renewable energy. Once a hydroelectric complex is constructed, the project produces no direct waste, and has a considerably lower output level of the greenhouse gas carbon dioxide (CO2) than fossil fuel powered energy plants. Worldwide, an installed capacity of 777 GWe supplied 2998 TWh of hydroelectricity in 2006.[1] This was approximately 20% of the world's electricity, and accounted for about 88% of electricity from renewable sources

Hydropower has been used since ancient times to grind flour and perform other tasks. In the mid-1770s, French engineer Bernard Forest de Bélidor published Architecture Hydraulique which described vertical- and horizontal-axis hydraulic machines. By the late 19th century, the electrical generator was developed and could now be coupled with hydraulics. The growing demand for the Industrial Revolution would drive development as well. In 1878 the world's first hydroelectric power scheme was developed at Cragside in Northumberland, England by William George Armstrong. It was used to power a single light bulb in his art gallery. The old Schoelkopf Power Station No. 1 near Niagara Falls in the U.S. side began to produce electricity in 1881. The first Edison hydroelectric power plant, the Vulcan Street Plant, began operating September 30, 1882, in Appleton, Wisconsin, with an output of about 12.5 kilowatts. By 1886 there were 45 hydroelectric power plants in the U.S. and Canada. By 1889 there were 200 in the U.S. alone.
From Wikipedia, the free encyclopedia
Jump to: navigation, search
Hydroelectricity is electricity that is made by the movement of water. It is usually made with dams that block a river or collect water that is pumped there. When the water is "let go" the huge pressure behind the dam forces the water down shafts that lead to a turbine, this causes the turbine to turn, and electricity is produced.
The energy of falling water has been used by humans for thousands of year
Advantages of hydroelectricity:
The way the electricity is produced does not harm the environment as much as fossil fuels like oil or coal. Hydroelectricity is immense and safe and produces no waste. Hydroelectricity can be made very quickly. This makes it useful for times when demand is high. Water that has been stored in a dam can be "let go" when needed, so the energy needed can be made quickly. Also hydroelectricity can not run out as long as there is a good water supply. Once the dam is built the electricity is free, no waste or pollution produced and electricity can be generated constantly also there is then a lot of extra energy to save and use.

Disadvantages of hydroelectricity

The building of large dams to hold the water can damage the environment. In 1983 Australian government stopped the Tasmanian state government from building a dam on the Gordon River in Tasmania after a huge public protest. The dam would have flooded the beautiful Franklin River. The Three Gorges Dam in China will be the world's largest hydroelectricity project. The dam has flooded a huge area, meaning that 1.2 million people have had to be moved. Scientists are concerned about many problems with the dam, such as pollution, silt, and the danger of the dam wall breaking.




Hydro-electricity uses the energy of running water to make electrical energy. Hydro-electric stations are built where there is running water.
Most hydro-electric stations are located in dams where water is stored. But hydro-electric stations can also be built on rivers and near waterfalls.
The flow of the water from the dam can be controlled by opening and closing gates or pipes to the dam. The dam wall also creates a high water level and this increases the pressure in the pipes which takes the water to the turbine
To make hydro-electric power, water from rain or melting snow is collected and stored in a lake or a dam. A large pipe carries the water from the dam or lake to the turbine. The pressure of the water pushes against the blades of the turbine and make it spin. The rotating turbine is connected to a generator which makes the electrical energy or electricity.
The electricity then travels through transformers and transmission lines to homes and factories.
Hydro-electricity is a renewable source of energy.
Hydro-electricity is clean power. It produces no waste, and doesn't produce any greenhouse gases.
The most famous hydro-electric power station in Australia is the Snowy Mountains Hydro-Electric Scheme. Go here to read about it: 
Hydro comes from a Greek word meaning water.